English
 
Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

A Novel Nonlinear Method for Cardiovascular Data Synchronization

Authors

Padovano,  Daniele
External Organizations;

Martinez-Rodrigo,  Arturo
External Organizations;

/persons/resource/Marwan

Marwan,  Norbert       
Potsdam Institute for Climate Impact Research;

Muñoz,  Santiago Mula
External Organizations;

Rieta,  Jose J.
External Organizations;

Alcaraz,  Raul
External Organizations;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Supplementary Material (public)
There is no public supplementary material available
Citation

Padovano, D., Martinez-Rodrigo, A., Marwan, N., Muñoz, S. M., Rieta, J. J., Alcaraz, R. (2025): A Novel Nonlinear Method for Cardiovascular Data Synchronization. - IEEE Access, 13, 89314-89331.
https://doi.org/10.1109/ACCESS.2025.3571070


Cite as: https://publications.pik-potsdam.de/pubman/item/item_32558
Abstract
This study introduces and evaluates a novel nonlinear technique for synchronizing electrocardiogram (ECG) and photoplethysmogram (PPG) signals by embracing the intrinsic relationship between heart rate variability (HRV) and pulse rate variability (PRV). The proposed method utilizes normalized mutual information (NMI) derived from cross-distance matrices (CDM) of HRV and PRV, alongside the distance matrix of a reference HRV extract. We tested the methodology on two databases containing simultaneous ECG and PPG signals, including one publicly available on Physionet, and benchmarked it against various synchronization techniques, both linear (Pearson coefficient, dynamic time warping) and nonlinear (conventional mutual information, NMI with recurrence plots, cross-recurrence plot, and determinism). Results showed that the proposed method (NMI of CDM) outperformed all others, achieving synchronization rates near 50% within a 1.2-second lag threshold. This study also comprehensively examines how signal quality and recording methodology variations affect synchronization outcomes, confirming the importance of lag threshold adjustment for real accuracy assessment. However, some limitations must be kept in mind: the proposed approach is not suited for blood pressure estimation based on HRV-PRV differences, nonlinear methods generally require higher computational resources than linear ones, and further validation is needed with additional databases from real-world scenarios similar to those used in this study.